Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
BMJ Open ; 9(10): e027278, 2019 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-31676643

RESUMO

OBJECTIVES: The aim of this study was to identify the prevalence of peripherally inserted central catheter (PICC) malposition and the influence of guide wire removal on tip location in PICCs and determine whether related factors, including age, sex, side of insertion and brand of catheter, influence the PICC tip location. SETTING: Single-centre research institute in China recruiting patients from the hospital. PARTICIPANTS: A total of 837 adult patients with inserted PICCs were recruited from October 2016 to May 2017. INTERVENTIONS: This was a cross-sectional study aiming to identify the prevalence of PICC malposition and the influence of guide wire removal on tip location in PICCs. A linear regression model and a variance of factorial design analysis were performed. The PICC tip location was documented on a postinsertion chest X-ray. Multivariable analyses were performed based on the following related factors: age, sex, side of insertion and brand of catheter. RESULTS: The tip location moved a mean of 17.4 mm among the 837 included patients. The prevalence of PICC malposition was 83.6% (700/837), while 16.4% (137/837) of PICCs remained in correct location. The mean movement caused by guide wire removal without an adjusted tail end was (-1.95±26.90) mm. The difference between tail end adjustment movement and actual tip position movement in each PICC was (33.0±17.1) mm in type C, which was significantly higher than the findings for type A (12.8±13.3) mm and type B (12.9±12.7) mm. CONCLUSIONS: PICC malposition is a frequent event. Different catheter brands were associated with different ranges of movement in tip location after guide wire removal. The age and sex of the patients and the insertion side did not influence the extent of movement.


Assuntos
Cateterismo Periférico/métodos , Cateteres Venosos Centrais/estatística & dados numéricos , Átrios do Coração , Falha de Prótese , Veia Cava Superior , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , China , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
2.
Korean J Radiol ; 19(1): 130-138, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29354009

RESUMO

Objective: To exploit material decomposition analysis in dual-energy spectral computed tomography (CT) to assess the blood supply status of the ground-glass opacity (GGO) in lungs. Materials and Methods: This retrospective study included 48 patients with lung adenocarcinoma, who underwent a contrast-enhanced dual-energy spectral CT scan before treatment (53 GGOs in total). The iodine concentration (IC) and water content (WC) of the GGO, the contralateral and ipsilateral normal lung tissues were measured in the arterial phase (AP) and their differences were analyzed. IC, normalized IC (NIC), and WC values were compared between the pure ground-glass opacity (pGGO) and the mixed ground-glass opacity (mGGO), and between the group of preinvasive lesions and the minimally invasive adenocarcinoma (MIA) and invasive adenocarcinoma (IA) groups. Results: The values of pGGO (IC = 20.9 ± 6.2 mg/mL and WC = 345.1 ± 87.1 mg/mL) and mGGO (IC = 23.8 ± 8.3 mg/mL and WC = 606.8 ± 124.5 mg/mL) in the AP were significantly higher than those of the contralateral normal lung tissues (IC = 15.0 ± 4.9 mg/mL and WC = 156.4 ± 36.8 mg/mL; IC = 16.2 ± 5.7 mg/mL and WC = 169.4 ± 41.0 mg/mL) and ipsilateral normal lung tissues (IC = 15.1 ± 6.2 mg/mL and WC = 156.3 ± 38.8 mg/mL; IC = 15.9 ± 6.0 mg/mL and WC = 174.7 ± 39.2 mg/mL; all p < 0.001). After normalizing the data according to the values of the artery, pGGO (NIC = 0.1 and WC = 345.1 ± 87.1 mg/mL) and mGGO (NIC = 0.2 and WC = 606.8 ± 124.5 mg/mL) were statistically different (p = 0.049 and p < 0.001, respectively), but not for the IC value (p = 0.161). The WC values of the group with preinvasive lesions and MIA (345.4 ± 96.1 mg/mL) and IA (550.1 ± 158.2 mg/mL) were statistically different (p < 0.001). Conclusion: Using dual-energy spectral CT and material decomposition analysis, the IC in GGO can be quantitatively measured which can be an indicator of the blood supply status in the GGO.


Assuntos
Adenocarcinoma/diagnóstico , Neoplasias Pulmonares/diagnóstico , Pulmão/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma de Pulmão , Artérias/diagnóstico por imagem , Feminino , Humanos , Iodo/química , Pulmão/irrigação sanguínea , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Água/química
3.
Zhonghua Yi Xue Za Zhi ; 95(11): 819-22, 2015 Mar 24.
Artigo em Chinês | MEDLINE | ID: mdl-26080912

RESUMO

OBJECTIVE: To assess the image quality of gastrointestinal tract malignant tumors arteries using low tube voltage, low contrast medium concentration and 50% adaptive statistical iterative reconstruction (ASiR) algorithm. METHODS: A total of 58 patients with pathologically confirmed gastrointestinal tract malignant tumors and body mass index (BMI) under 22 kg/m² undergoing computed tomography (CT) scanning during March-December 2013. They were randomly divided into group A (270 mgI/ml of contrast medium, 80 kVp tube voltage scanning and 50% ASiR; 21 males and 11 females with an age range of 40-90 years) and group B (350 mgI/ml of contrast medium, 120 kVp routine tube voltage; 22 males and 4 females with an age range of 40-76 years). The inter-group differences of age and gender ratio were compared with Mann-Whitney U and Fisher exact tests respectively. Two independent radiologists reviewed reconstructions and separated the reconstructed image into 5 points according to image quality. The CT value of tumor blood supplying artery (CT1 value) and fat in anterior abdominal wall (SD value) were measured and image noise, contrast-to-noise ratio (CNR) and figure of merit (FOM) calculated. The interobserver variation was estimated by weighted kappa statistics and intra-class correlation coefficients (ICC) test. The point of image quality of two groups was compared by Mann-Whitney U test. The paired Student t test was used to compare the inter-group differences in CT1, SD, CNR, FOM and CT dose index (CTDIvol). RESULTS: No inter-group difference existed in patient age or gender ratio. The consistency of two radiologists was excellent (kappa value > 0.80; ICC value > 0.75). The subjective image quality scores of tumor blood supplying arteries showed no inter-group difference (P = 0.09). The tumor blood supply arteries CT value, CNR and FOM of group A (459 ± 69 HU, 20.2 ± 3.3 and 85 ± 37) were significantly higher than those of group B (250 ± 42 HU, 9.3 ± 1.9 and 9 ± 4) (both P < 0.01). The SD value of group A (20.0 ± 1.7) was obviously lower than that of group B (22.4 ± 3.2) (P < 0.01). And the CTDIvol of group A (5.2 ± 1.2 mGy) was obviously lower than that of group B (13.5 ± 4.7 mGy) (P < 0.01). CONCLUSION: For patients of BMI ≤ 22 kg/m², low tube voltage and low contrast medium concentration scan condition with 50% ASiR algorithm is feasible for acquiring better quality image and ensuring significant reduction in effective dose.


Assuntos
Neoplasias Gastrointestinais , Neovascularização Patológica , Doses de Radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Angiografia , Artérias , Índice de Massa Corporal , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
4.
Comput Methods Programs Biomed ; 92(3): 267-73, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18676053

RESUMO

The success of image analysis depends heavily upon accurate image segmentation algorithms. This paper presents a novel segmentation algorithm based on artificial ant colonies (AC). Recent studies show that the self-organization of ants is similar to neurons in the human brain in many respects. Therefore, it has been used successfully for understanding biological systems. It is also widely used in many applications in robotics, computer graphics, etc. Considering the features of artificial ant colonies, we present an extended model for image segmentation. In our model, each ant can memorize a reference object, which will be refreshed when it finds a new target. A fuzzy connectedness measure is adopted to evaluate the similarity between target and the reference object. The behavior of an ant is affected by the neighbors and the cooperation between ants is performed by exchanging information through pheromone updating. Experimental results show that the new algorithm can preserve the detail of the object and is also insensitive to noise.


Assuntos
Algoritmos , Anatomia Transversal , Diagnóstico por Imagem/métodos , Modelos Teóricos , Animais , Formigas , Comportamento Animal , Interpretação de Imagem Assistida por Computador/métodos
5.
Zhonghua Zheng Xing Wai Ke Za Zhi ; 23(2): 115-8, 2007 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-17554873

RESUMO

OBJECTIVE: To introduce a novel digital surgery technique based on partial reconstruction of skull and its application in tumor resection and on-sport reconstruction surgery. METHODS: The partial 3d reconstruction according to CT scanning data was obtained to get 3d model of both tumor and normal skull, then to define the resection area on tumor data through people-computer interaction process, do reconstruction the simulation on the remained model, pre-fabricate the cutting template and custom the implant. The resection template to confirm the message in surgery simulation can be transferred to real surgery accurately. RESULTS: All the four cases by using this method showed great consistency of the real and simulated surgery and got a good appearance of reconstruction. CONCLUSIONS: The surgery simulation technique based on partial 3d reconstruction has great assistance to tumor resection and one-stage reconstruction surgery.


Assuntos
Neoplasias de Cabeça e Pescoço/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...